When the core pin is not shutting off on the inner core wall, the distance from the edge of the insert should be 1.142 for the slide carrier to shut off against the core insert.
When the core pin is not shutting off on the inner core wall, the distance from the edge of the insert should be 29.00 for the slide carrier to shut off against the core insert.
The .828 dimension must be maintained to avoid improper spring pre-load or damage to internal components.
The 21.03 dimension must be maintained to avoid improper spring pre-load or damage to internal components.
CATALOG NUMBER |
DESCRIPTION |
---|---|
CA-100 | CamAction Unit |
CAMM-100 | Metric CamAction Unit |
PART NAME | MATERIAL/TREATMENT |
---|---|
Driver | H-13, 40-44 HRC, Titanium Nitride |
Slide Carrier | P-20, 30-34 HRC, Black Nitride |
Housing | 4140, 28-32 HRC, Black Nitride |